Kawartha Septic truck on a rural Ontario property
Septic Guide

How Deep Is a Septic Tank Buried? Typical Depths in Ontario

A septic tank installed under the current Ontario Building Code has its access lid no more than 300 mm (about a foot) below the ground, either because the tank is set that shallow or because a riser b

By the Kawartha Septic service team · Published

A septic tank installed under the current Ontario Building Code has its access lid no more than 300 mm (about a foot) below the ground, either because the tank is set that shallow or because a riser brings the opening up. Older tanks around Kawartha Lakes are another story. It is common to find their lids anywhere from about 30 cm to a metre down, and deeper where the yard has been built up since.

That figure is the depth of the top. The tank is taller than most people picture. The Code requires it to hold at least 1,000 mm of liquid, with air space and a lid above that, so the floor of even a shallow tank sits well over a metre below the lawn.

Depth decides how much digging stands between the pump truck and your lid, and whether the patio or load of fill you are planning is about to go on top of the system. If you have not located the tank yet, start with how to find your septic tank.

Septic Depths at a Glance

Part of the systemDepth below the surfaceSource
Tank access openings, current CodeNot more than 300 mmOBC 8.2.2.3(9)
Tank top buried deeper than 300 mmAllowed, but risers must bring access to within 300 mmOBC 8.2.2.3(10)
Lid on older tanksCommonly 30 cm to 1 m, sometimes moreVaries by site and installer
Liquid inside the tankAt least 1,000 mm deep (900 mm in rock or high groundwater)OBC 8.2.2.3(8)
Conventional leaching bed trenches600 to 900 mm deepOBC 8.7.3.3
Shallow buried trench after a treatment unit300 to 600 mm deepOBC 8.7.3.3
Unsaturated soil under a conventional trenchAt least 900 mm above rock or the high water tableOBC 8.7.3.3

What the Ontario Building Code Says About Tank Depth

The current Code is the 2024 Ontario Building Code, O. Reg. 163/24, in force since 1 January 2025. Part 8 covers sewage systems, and it does not set one burial depth for a tank. It sets access instead.

Article 8.2.2.3 says a septic tank’s access openings must be no more than 300 mm below the ground surface. Where the top of the tank sits deeper than that, the tank has to be fitted with risers that come up to within 300 mm of grade, and those risers must meet CSA B66, the standard for prefabricated septic tanks. You can read the wording in CodeIndex’s copy of OBC 8.2.2.3. The province’s Building Code page is where the official Compendium is published.

So the Code cares less about how deep the tank is than about how deep the lid is. A tank can sit well down if the site calls for it, as long as the openings can be reached without an excavator.

There is a limit the other way too. Article 8.2.2.2 says a tank must not be covered by more soil than the maximum burial depth it was designed to withstand, a rating printed on the manufacturer’s spec sheet. That matters when a yard is regraded and fill goes over an old tank.

The 300 mm rule describes how tanks are to be installed. It does not reach back and change a tank that went in decades ago. If you are replacing a tank or doing permitted repair work, ask the City of Kawartha Lakes Building and Septic Division what your permit will require.

Why Tanks End Up at Different Depths

Two houses on the same road can have lids at very different depths. The reasons are usually local and fairly mundane.

The first is where the house drain leaves the building. Sewage runs to the tank by gravity, so the pipe has to keep falling the whole way. A house whose drain exits low through a basement wall, or a tank set a long way from the house, ends up with a lower inlet and a deeper tank. A cottage on a slab with a short run to the tank can have one much closer to the surface.

Rock and groundwater push the other way. Where granite or a high water table sits close to the surface, installers set the tank higher and mound fill over it rather than blasting or pumping out a hole. The Code allows a shallower liquid depth, 900 mm instead of 1,000 mm, where the excavation is in rock or where groundwater pressure could shift the tank.

Frost plays a part too. A deeper pipe and tank sit further from the worst of the cold, which is one reason some installers went down rather than up. Our post on whether a septic system can freeze covers which parts are most exposed in a Kawartha winter.

Then there is what happened to the yard afterwards, which on older properties is often the biggest factor. A new driveway, a raised lawn, a garden bed or fill spread to level a lot can put a lot more soil over a lid that once sat near the surface. A permit drawing, if one exists, shows where the installer put the tank. It says nothing about the decades of topsoil since.

Burial Depth Is Not Liquid Depth

These two get mixed up, and pumping companies talk about both.

Burial depth is how far down the top of the tank or its lid is. It decides how much digging a service visit needs.

Liquid depth is how deep the contents are inside the tank, measured from the floor up to the level at the outlet. The Code requires at least 1,000 mm, or 900 mm in rock or high groundwater. Liquid depth is part of what sets a tank’s working capacity, which is why our septic tank size guide has you measure it when you are working out what size tank you own.

Add them together and you get a sense of where the floor is. Say your lid is 600 mm below the grass. Below that is the lid itself, an air gap, then at least a metre of liquid. Six hundred millimetres plus a metre of liquid puts the floor past 1.6 metres, and that is before you count the lid and the air gap.

The hose does the work down there, never a person. Nobody should climb into, lean into or put their head over an open septic tank; the gases that collect inside are dangerous at close range.

How Deep Are Septic Lines?

There are three runs of pipe in a typical system, and each sits at a different depth.

House to tank

The building sewer leaves the house and falls steadily to the tank inlet. How deep it starts depends on where the drain exits the foundation, and it gets a little deeper along the way because it has to keep sloping. The inlet enters near the top of the tank, above the liquid, so this pipe arrives at roughly the depth of the tank’s top. The shallow stretches are the ones that freeze in a cold snap without snow cover and the ones that crack under a vehicle.

Tank to bed

Effluent leaves through the outlet at the liquid level and runs to the leaching bed. On a gravity system the outlet has to sit higher than the pipe in the bed, so the tank depth and the bed depth are designed together. Where the bed ends up higher than the tank outlet, as with a raised bed, a pump chamber lifts the effluent instead.

Pipe in the bed

In a conventional in-ground bed, the Code sets trench depth at 600 to 900 mm, with perforated pipe laid in washed stone. The trench bottom needs at least 900 mm of unsaturated soil above rock, the high water table or very slow soil. Where effluent first goes through a treatment unit, a shallow buried trench can be 300 to 600 mm deep. The numbers are in OBC 8.7.3.3. A raised bed sits partly or wholly above the original ground. Our leaching bed size and depth guide covers sizing and what these depths mean on thin soil over rock.

What Depth Means for Your Pump-Out

This is where depth turns into money.

If your tank has a riser to grade, the operator lifts the lid, runs the hose and gets on with it. If it does not, someone has to dig down to the lid first. That is a digging fee of $100 to $200, added to a standard pump-out of $300 to $600 for a 1,000 to 1,500 gallon tank, and it comes back every time the tank is serviced.

A riser installation runs $200 to $500, so it usually pays for itself within a few pump-outs. Our septic tank risers guide compares materials and walks through the install, and risers are part of our septic tank repair work.

A few other ways depth shows up on service day:

  • Tanks have openings over each compartment so all of them can be pumped. If only one has a riser, the other may still need digging.
  • A deep lid with no riser is slow work once the ground freezes. If yours is buried, book the pump-out before winter.
  • Access changes the price, distance does not. Anywhere in the City of Kawartha Lakes there is no travel surcharge. What can change a quote is a long or steep driveway, a gate the truck cannot pass, or a tank we have to dig for, and that is quoted up front. For properties in Peterborough County, Durham, Hastings or Haliburton, the price is quoted up front before the truck is booked.

Finding Out How Deep Your Tank Is

You do not need to open anything to get a rough answer.

Start with the City. Its of Kawartha Lakes Building and Septic Division holds sewage system records back to 1974, and a permit drawing can show where the tank went. Call the City at 705-324-9411. The City’s fee schedule also lists a sewage system location verification site inspection at $150.

A soil probe is the next best thing. Push a thin rod straight down over where the tank should be until it stops on something hard and flat, then measure how much rod went in. Go gently over plastic tanks.

At your next pump-out, ask the operator to note the lid depth, and which openings have risers, on your service record. The next owner of the house will want it too.

Do not try to lift a concrete lid on your own, and never leave one off or loose. An open tank is a fall hazard for children and pets.

Before You Add Fill, Build or Regrade

Soil added over the tank buries the lid deeper, adds digging to every future pump-out and can push the tank past its rated burial depth. Over the leaching bed, the Code does not allow a covering of low-permeability material, so a patio, driveway or plastic sheeting there is a problem. Our post on what can go over a leaching bed sorts the safe uses from the harmful ones. If the work moves or alters any part of the system, check with the City first.

Frequently Asked Questions

How deep is a septic tank usually buried in Ontario?

Under the 2024 Ontario Building Code, a septic tank’s access openings must be no more than 300 mm below the surface, or the tank must have risers that bring access to within 300 mm. Older tanks commonly have lids somewhere between 30 cm and a metre down, and sometimes more where fill has been added. The tank itself extends well below the lid, since it must hold at least 1,000 mm of liquid.

Are septic tank risers required in Ontario?

For a tank installed under the current Code, yes, whenever the top of the tank is more than 300 mm below the ground surface. The risers must reach to within 300 mm of grade and meet the CSA B66 standard. Older tanks installed before this applied may not have them, so ask the City of Kawartha Lakes whether a permit for your work will require one.

How deep are septic lines from the house to the tank?

There is no single number, because the pipe starts wherever the house drain leaves the foundation and has to slope down all the way to the tank. It arrives near the top of the tank, above the liquid, so it runs at roughly the depth of the tank’s top. Shallow sections are the ones most at risk of freezing and of damage from vehicles.

How deep is a leaching bed in Ontario?

Conventional leaching bed trenches are 600 to 900 mm deep, with at least 900 mm of unsaturated soil between the trench bottom and rock or the high water table. A shallow buried trench, allowed after an approved treatment unit, is 300 to 600 mm deep. Raised beds are built partly or fully above the original ground.

Does a deeper septic tank cost more to pump?

The pump-out itself is priced on tank size, typically $300 to $600 for a 1,000 to 1,500 gallon tank. What depth adds is digging: without a riser, uncovering the lid adds $100 to $200 to each visit. A riser installation at $200 to $500 removes that fee for good.

Get the Depth on Record at Your Next Pump-Out

Call (705) 702-5526 or book a pump-out. Most routine septic tank pumping visits are scheduled within 48 hours, and we will note how deep your lid is and whether a riser would save you the digging fee next time. There is no travel surcharge anywhere in the City of Kawartha Lakes.

Still not sure what your system needs?

Leave a number and where the property is. We will call you back with a straight answer and a real price — not a form letter.

Or call (705) 702-5526 — 24-hour emergency line.

Continue Reading