Kawartha Septic truck on a rural Ontario property
Septic Guide

Waterloo Biofilter in Ontario: How It Works and What Owners Need to Know

A Waterloo Biofilter is a treatment unit that sits between your septic tank and your leaching bed and runs tank effluent through blocks of absorbent foam, where bacteria clean it before it goes to the

By the Kawartha Septic service team · Published

A Waterloo Biofilter is a treatment unit that sits between your septic tank and your leaching bed and runs tank effluent through blocks of absorbent foam, where bacteria clean it before it goes to the ground. In Ontario it comes with two legal strings attached: a servicing agreement with someone the manufacturer has authorized, and a lab sample every year.

Most owners did not choose theirs. A designer specified it because the lot was too small, the soil too thin or the lake too close for a conventional bed, and the house changed hands with a control panel on a post and not much explanation.

This post covers the one brand. For how it compares with other units, see our guide to advanced treatment units in Ontario. The technical detail below comes from Waterloo’s Ontario owner’s manual and the Building Code.

How a Waterloo Biofilter Works

The manufacturer describes it as an attached-growth trickling filter. In plain terms, the water trickles through a sponge and the bacteria living in the sponge do the work.

The path the water takes

  1. Pre-treatment tank. Everything from the house goes to an ordinary buried septic tank first, where solids settle and scum floats.
  2. Pump chamber. Settled effluent moves to a pump chamber, either a compartment inside the tank or a separate tank. An effluent pump, float switches and an inline filter live here. The filter catches solids before they reach the spray nozzles.
  3. The biofilter. The pump sprays effluent over the foam. The foam soaks it up and holds it by capillary action while bacteria inside it break down organic matter, coliform bacteria and ammonium. Air moves through the foam on its own, so there is no blower.
  4. Recirculation. In the basket configuration described in the Waterloo owner’s manual, a submersible pump in the biofilter tank sends part of the treated water to the leaching bed and returns part to the pre-treatment tank inlet for extra nitrogen removal.
  5. Dispersal. Treated effluent goes to a leaching bed designed for your site.

Waterloo makes several residential formats (baskets, flat beds, a shed unit, a bulk-filled version). The principle is the same; your permit and design drawings say which one you have.

Why the foam matters to an owner

The foam is not a consumable. Waterloo’s manual says the medium carries a 20-year warranty against biodegrading to the point where it can no longer absorb water, and that no replacement is required when that warranty runs out. So there is no media swap to budget for at a fixed age, though the foam can still be damaged by the wrong things going down the drain (more on that below).

Why a Designer Specified One for Your Lot

A treatment unit cleans effluent far more thoroughly than a septic tank alone, and that lets a designer use the dispersal types the Code pairs with treatment units: shallow buried trenches and Type A and Type B dispersal beds.

In cottage country the usual trigger is a tight lot. Setbacks from the well, the lake and the lot lines leave no room for a full-size bed, and our post on septic systems for small lots in Ontario walks through that setback math. Thin soil over rock is the other common one: there is not enough native soil to finish treatment, so the unit does the treating and the bed mostly disperses. On a waterfront lot, cleaner effluent is also simply better for the lake.

If your design mentions a Type A bed, our explainer on Type A dispersal beds and raised sand beds covers what that means on the ground.

What it costs

A tertiary treatment system in Ontario, installed, typically runs $28,000 to $45,000. That is the range for tertiary systems as a category, not a quote for a Waterloo unit; the lot, the dispersal bed and site access move the final number. Every installation or replacement starts with a site visit and ends with a written, itemized quote, and the design is stamped by a licensed sewage system designer. Our installation page explains the steps.

The Service Agreement and Annual Sampling

The servicing agreement

OBC 8.9.2.3 says no one may operate a treatment unit other than a septic tank without an agreement for servicing and maintenance by a person who has the manufacturer’s literature and is authorized by the manufacturer to service that type of unit. If the agreement ends, or the owner refuses access, the service provider has to tell the chief building official. In the City of Kawartha Lakes that means the City’s Building and Septic Division.

Waterloo’s manual ties the warranty to the same thing: it takes effect only once Waterloo receives a signed maintenance contract, and a lapsed contract voids it.

Our post on the mandatory service contract on an advanced treatment unit covers what lapsing does to resale and insurance. The contract price is set by the service provider, so get it in writing.

What the annual visit checks

From the manual’s component table:

ComponentWhat happens at the visit
Pre-treatment tankInspected; provider says whether it needs pumping
Control panel and floatsTested, including the high-level alarm
Effluent pump(s)Inspected
Inline filterEmptied
Spray nozzlesCleaned
Foam medium and basketsInspected
Leaching bedInspected
Sample portSample taken where local rules require it

The sample

Ontario requires sampling when a treatment unit feeds a shallow buried trench, Type A bed or Type B bed. Under OBC 8.9.2.4, the operator takes grab samples for CBOD5 and suspended solids within the first 12 months of use, then once in every 12-month period, at least 10 and no more than 18 months after the previous one. Results go to the chief building official. A result is compliant when neither figure exceeds 20 mg/L, and a failed result has to be resampled within six months. The service provider usually takes it, but the duty sits with the operator, which is you.

Pumping the Tank Is Still Your Job

The tank in front of the biofilter still fills with sludge, and Waterloo’s manual makes pumping it the owner’s job, done when the service provider says it is due. The manual puts that at every 4 to 8 years depending on use, or when sludge takes up a third of the tank. The annual visit measures it, so you pump on evidence rather than the calendar.

The pump-out is a separate booking with a septic pumper. A standard pump-out for a 1,000 to 1,500 gallon tank runs $300 to $600 in the City of Kawartha Lakes, with no travel surcharge anywhere in the City. When you book, mention the treatment unit so the crew knows which lid is the pre-treatment tank and which lids belong to the pump chamber and the biofilter.

The manual says every lid must stay accessible at grade, and vented lids clear of mulch and plants, since that is how air reaches the foam. A buried lid means a digging fee of $100 to $200 on pump-out day. Never lean into or climb into any of these tanks: the gases in a sewage tank can kill.

Problems Owners Actually See

The alarm

The panel has a buzzer and a light. Waterloo’s manual says the alarm means the water level in the pump tank or the biofilter is too high. Call your service provider, cut water use until it is fixed, and use the silence switch only to stop the noise.

The usual culprit is something that stopped moving water: a pump, a float or a blocked filter. Our guide to a septic alarm going off covers the first steps.

Power outages

No power, no pumps. The pump tank and pre-treatment tank start filling, so the manual says to limit water use until power returns. Our post on septic systems in a power outage covers generators and long outages.

Pump failure

Pumps are wear parts. Effluent pumps typically last 7 to 10 years, and replacement runs $600 to $1,500, as our effluent pump replacement cost guide explains. A Waterloo system may have two pumps, one feeding the biofilter and one moving treated water out.

Odour and wet ground

Waterloo’s manual lists the signs that should get a call to the service provider right away:

  • Sewage odour around the system. A smell from the roof vent is normal and can drift down.
  • Standing water around the leaching bed.
  • Sinking or very wet soil around the bed.
  • Very slow drains or backed-up toilets.

The manual reads odour at the unit as a sign of unhealthy bacteria, which leads back to what goes down the drains.

What damages the foam

The warranty excludes damage from paints, harsh cleaners, softener backwash, solvents, strong acids and bases, and excessive flow. The manual’s owner rules add: no softener or water treatment backwash, no pool, spa, sump pump or RV water, no garbage disposal, no antibacterial soaps, no wipes, and nothing larger than a riding mower driven near the system. If you have a softener, our post on water softeners and septic systems covers rerouting the discharge.

Seasonal Cottages

The manual says the system needs no special steps for seasonal or long periods of non-use, because the pumps sit idle when no water is coming in. If you shut the power off for the winter, shut the water off too. There is no need to pump the tank at the end of the season, and antifreeze must never go into the system.

Buying a House With a Waterloo Biofilter

Sort it out before closing. Our guide to a septic inspection before buying a house in Ontario covers the inspection. For a Waterloo, also ask for:

  • The system specifications from the label on the control panel. A service provider needs them.
  • The permit and design file. In the City of Kawartha Lakes, the Building and Septic Division holds septic records. Their number is 705-324-9411.
  • Service reports and sample results for recent years. Gaps mean the unit may have gone unserviced.
  • The status of the service agreement, and whether it will carry over or you will sign a new one.

Then deal with the warranty. Waterloo’s manual says the limited warranty can transfer once, but only if Waterloo is notified in writing within 90 days of closing with the new owner’s name, mailing address and phone number. Miss that window and the warranty is void. Put it on your lawyer’s closing checklist.

Frequently Asked Questions

Is a Waterloo Biofilter service contract mandatory in Ontario?

Yes. Ontario Building Code 8.9.2.3 says no one may operate a treatment unit other than a septic tank without a servicing agreement with someone authorized by the manufacturer. Waterloo also makes its limited warranty depend on a signed maintenance contract. The contract price is set by the service provider, so get it in writing.

Does the Waterloo Biofilter foam need to be replaced?

Not on a schedule. Waterloo’s owner’s manual gives the foam a 20-year warranty against biodegrading and says no replacement is required when the warranty ends. The foam can still be damaged by paints, solvents, harsh cleaners, water softener backwash and heavy flows, which the warranty does not cover.

How often does the tank on a Waterloo Biofilter need pumping?

Waterloo’s manual puts it at every 4 to 8 years depending on use, or when sludge fills a third of the pre-treatment tank. The annual service visit measures it and tells you when it is due. Pumping is booked separately from the service agreement, and in the City of Kawartha Lakes a standard pump-out for a 1,000 to 1,500 gallon tank runs $300 to $600.

What should I do if my Waterloo Biofilter alarm goes off?

Cut water use and call your service provider. The alarm means water is too high in the pump tank or the biofilter, usually because a pump, float or filter has stopped doing its job. The silence switch on the panel stops the noise but does not fix the problem.

How much does a Waterloo Biofilter cost to install?

Tertiary treatment systems in Ontario typically run $28,000 to $45,000 installed. That is a range for the category, not a price for one brand, and the lot, the dispersal bed and site access move the final number. Any installation should start with a site visit and a written, itemized quote.

Book the Pump-Out Your Service Provider Asks For

When the annual report says the tank is due, call (705) 702-5526 or book a pump-out. Most routine pump-outs are scheduled within 48 hours, and we leave you a record of the service for the file your service provider and your next buyer will both ask to see.

Still not sure what your system needs?

Leave a number and where the property is. We will call you back with a straight answer and a real price — not a form letter.

Or call (705) 702-5526 — 24-hour emergency line.

Continue Reading